1. ABSORBER PLATE-

GI line Steel finstrips
formed around
galvanized
steel tubes
providing
excellent heat transfer.
The absorber plate is black
coated, to produce a superior surface, highly efficient for solar energy absorption.
1. ABSORBER PLATE -
GC line Steel finstrips
formed around
copper
tubes
providing excellent
heat transfer.
The absorber plate is black
coated, to produce a superior surface, highly efficient for solar energy absorption.
1. ABSORBER PLATE -
GCS line.Copper absorber
ultrasonic welded on
copper tubes providing
excellent heat transfer.
The absorber plate is
selective coated, to get
the highest efficient solar
energy absorption.



2. TUBING GRID -

GI line. ½ " anodized steel skedule40,
electronic welded to 1" manifold with an optimal ratio between diameters.
2. TUBING GRID -
GC line. 16mm copper
waterways silver brazed
to 29mm copper manifolds with an optimal ratio between diameters.
2. TUBING GRID -
GCS line. 16mm copper
waterways silver brazed
to 29mm copper manifolds with an optimal ratio between diameters.
3. INSULATION -
Polyurethane foam cast
under and around the
sides of the absorber
plate. Special PU with low freon content to meet European standard



4. PIPING CONNECTION

can be made at four locations, eliminating the need for external piping in a collector array. Outlet diameter: 1" BSP thread.
5. COLLECTOR CASE-
weather-tight.
Constructed of galvanized steel sheets.
6. GLAZING- single
pane 3 mm clear glass.
Options: tempered
low-iron glass.
7. BACK PAN- made of
PVC sheet, UV resistant.
8. GASKET- high temp.
U-shaped, EPDM rubber.
9. ALUMINUM FOIL-
To reflect the emitted heat radiation to the absorber plate. Minimizing heat
loss at the back.
10. AIR GAP- between
absorber plate and the
back insulation reduses
heat losses.